Skip to content
Mingcedar / TIA

TIA / PLC DB Point Extraction

Explains how Mingcedar Scan reads scalar points offline from proven standard-layout DBs in TIA Portal projects, then applies scope, rule review, and result export.

01Point 1

Confirm Windows x64, .NET 4.8, TIA Portal, Automation License Manager, and Openness access first.

02Point 2

Project-tree, PLC, DB-number, and access-attribute scope affect the result, but the address area is fixed to DB.

03Point 3

The GUI exports one Excel, CSV, or JSON file; the CLI creates Mingcedar-compatible JSON.

TIA

Guide

Before extracting points, review environment access, scan scope, result fields, and export requirements.

TIA / PLC DB Point Extraction
TIA TIA / PLC DB Point Extraction

Mingcedar Scan is a standalone tool that reads a local TIA project or archive without connecting to a live PLC. Standard-DB scalar results include symbolic paths, absolute addresses, and verification status. Unverified rows remain available for review; communication imports require address and type checks. Optimized/unknown layouts, I/Q/M, and members without a constructed address are excluded.

  • Confirm Windows x64, .NET 4.8, TIA Portal, Automation License Manager, and Openness access first.
  • Project-tree, PLC, DB-number, and access-attribute scope affect the result, but the address area is fixed to DB.
  • The GUI exports one Excel, CSV, or JSON file; the CLI creates Mingcedar-compatible JSON.
Preparation

Mingcedar Scan runs on Windows x64 engineering workstations and requires .NET Framework 4.8, TIA Portal that can open the project, a running Automation License Manager service, and Openness access for the current user.

  • Match the Scan build, installed TIA, and Openness API. Older projects from V14 onward can use the migration paths supported by TIA; V21 projects require the V21 build.
  • Confirm Automation License Manager and Openness access.
  • Keep the project or archive at a stable local path and verify the resolved full path.
Scan and review

After scanning, review the result project, standard-layout DB scope, symbolic path, absolute address and verification status, byte/BOOL bit offsets, data type, and rule matches before retaining points for export.

  • Scan standard-layout global and instance DBs in local TIA projects or archives only.
  • Do not scan through a PLC IP or live protocol; I/Q/M do not enter results.
  • Result-table search and Rule Center use different fields and wildcard rules.
Export results

Export Current Result in the desktop UI saves one .xlsx, .csv, or .json file. Only a non-preview CLI scan creates normalized-tags, Mingcedar-compatible JSON, generic-tags, report, and export-manifest files. Other SCADA/HMI or custom systems require mapping and validation against their official specifications.